 | | From: | dameet | | Subject: | simulation interface toolkit: Error 63 | | Date: | Wed, 19 Jan 2005 14:40:12 -0600 (CST) |
|
|
 | I am trying to download a dll file onto the target. As described in the doc= umentation, I open the original VI, run it. After that I go to Simulation -= -> Retarget. Here I enter the IP of the RT target machine (to which the dll= should be directed to) and edit the port number as well. The VI generated = by the build is pointed to by browsing along with the dll file. After t= his, I get the Error:
Error 63 occurred at Open Application Referenc= e in DynamicDownload.vi->SIT_InitRTDownload.vi->SIT Initialize.vi->FreeTemp= vi
Make sure that VI Server on target has (i) TCP/IP access ena= bled on the default port, (ii) host machine is in TCP/IP access list, a= nd (iii) the model VI is exported.
Returning to Select Host dialo= g.
I am ensure that the IP of the RT machine is listed in "Allow Acc= ess" of the options tab for VI Server: Configuration. Also, the port number= is 3363. I also edited that in the Freerun_main.vi.
Any suggestion= s? Thanks Regards, Amit
|
|
|