 | | From: | TommyTestBoy | | Subject: | Re: LabVIEW 7.0 Crashes when inserting "Instrument I/O Assistant" Express VI | | Date: | Fri, 21 Jan 2005 08:10:47 -0600 (CST) |
|
|
 | Sayaf - Now I think I understand.
- There is only one version of IIO= A available for download off of the web - it is version 1.0.1, which I am a= ssuming is the one you are using. The link to it on the NI website is =
http://digital.ni.com/softlib.nsf/954feaeea92d90918625674b00658b83/f3ca= 0298c715bcd886256e82005758e5?OpenDocument
There is a version 1.0.2 w= ith a couple of bug fixes, but it is only available on the latest Device Dr= iver CD, and is not available for download.
- You cannot just run II= OA.msi. You must run the entire distribution included in the download from= ni.com. The IIOA.msi has many dependencies that are included in the downl= oaded distribution. Download the installer I gave the link for above, and = run setup.exe instead of IIOA.msi.
This should solve your problem.r> - No, Instrument I/O Assistant does not work with Tek VISA. It only = works with NI VISA because it uses quite a few of the features that NI VISA= provides in MAX. What is your reason for needing Tek VISA instead of NI V= ISA?
Hope this helps.